•        Command Syntax
Prefix Storage Tag SubTag {Data} [, SubTag {Data}] [; Tag SubTag {Data}] […] ; Suffix
Among which, {data} means integrant while [data] means optional data.
| 
				 Part  | 
			
				 Item  | 
			
				 content  | 
			
				 Remark  | 
		
| 
				 1  | 
			
				 Prefix  | 
			
				 “~<SOH>0000” : (HEX: 7E 01 30 30 30 30)  | 
			
				 Fixed 6 characters  | 
		
| 
				 2  | 
			
				 StorageType  | 
			
				 “@” or “#”,1 character.  | 
			
				 
					“@” means permanent setting which will   not be lost by removing power from the scanner “#” means temporary setting which will be lost by removing power from the scanner or rebooting it.  | 
		
| 
				 3  | 
			
				 Tag  | 
			
				 A 3-character case-sensitive field that identifies the desired command group  | 
			
				 
					For example, the Tag for the Enable Code  | 
		
| 
				 4  | 
			
				 SubTag  | 
			
				 A 3-character case-sensitive field that identifies the desired parameter within the tag group  | 
			
				 
					For example, the  | 
		
| 
				 5  | 
			
				 Data  | 
			
				 The value for a feature or parameter setting, identified by the Tag and SubTag  | 
			
				 
					For example, the Data for the Enable  | 
		
| 
				 6  | 
			
				 Suffix  | 
			
				 “;<ETX>” (HEX: 3B 03),  | 
			
				 Fixed 2 characters  | 
		
	•        Responses
Different from command sequence, the prefix of a response consists of the six characters of “<STX><SOH>0000” (HEX: 02 01 30 30 30 30).
When responding, the scanner echoes back the command sequence with the status character above inserted directly before
each of the punctuation marks (the comma or semicolon) in the command
| 
				 Item  | 
			
				 content  | 
		
| 
				 <ACK> (HEX: 06)  | 
			
				 Indicates a good command which has been processed  | 
		
| 
				 <NAK> (HEX: 15)  | 
			
				 
					Indicates a good configuration command   with its Data  | 
		
| 
				 <ENQ> (HEX: 05)  | 
			
				 Indicates an invalid Tag or SubTag command  | 
		
• Example
	

 
	
	Example 1: Enable Code 11, set minimum length as 12 and maximum length as 22
Enable Code 11
Tag: C11
SubTag: ENA
Data: 1
Set the Minimum Length ( Default 4) Set the Maximum Length ( Default 48)
SubTag: MIN SubTag: MAX
Sending:
HEX: 7E 01 30 30 30 30 40 43 31 31 45 4E 41 31 2C 4D 49 4E 31 32 2C 4D 41 58 32 32 3B 03
ASCII: ~<SOH>0000@C11ENA1,MIN12,MAX22;<ETX>
Response:
HEX: 02 01 30 30 30 30 40 43 31 31 45 4E 41 31 06 2C 4D 49 4E 31 32 06 2C 4D 41 58 32 32 06 3B 03
ASCII: <STX><SOH>0000@C11ENA1<ACK>,MIN12<ACK>,MAX22<ACK>;<ETX>

												                    
															
								
						
					
						
					
						
					
					
					


2823 views