LINKS
LINKS
Custom trigger command
Announcer: Danica Time: 26th Jul 2021
Share to :
2615 views 0 comments


Trigger Command

When Enable Trigger Commands is selected, you can activate and deactivate the engine in the Level mode with serial trigger commands. Sending the Start Scanning command (default:<SOH> T <EOT>, user-programmable) to the engine in the Level mode activates a decode session. The decode session continues until a barcode is decoded or the decode session timeout expires or the engine receives the Stop Scanning command (default:<SOH> P <EOT>, user-programmable)

                


 

Modify Start Scanning Command

The Start Scanning command can consist of 1-10 characters (HEX values from 0x01 to 0xFF). In this command, the character “?” (HEX: 0x3F) cannot be the first character. The default Start Scanning command is<SOH> T <EOT>.

 

Modify Stop Scanning Command

The Stop Scanning command can consist of 1-10 characters (HEX values from 0x01 to 0xFF). In this command, the character “?” (HEX: 0x3F) cannot be the first character. The default Stop Scanning command is<SOH> P <EOT>


 

 

Refer to Digit Barcodes and Save/Cancel Barcodes to set the message you want.

All comments (0)
POPULAR TAGS