4886 views
													
0 comments
												1. USB HID-POS Report ID
- Out Report ID : 0x04
 - In Report ID : 0x02
 
reference with packet format as below:
	
	
- Example 1: acquire serial number from FM30
 
send data to the scanner as below
| 
				 04 09 7E 00 05 01 01 F0 08 11 11 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00  | 
		
acquire response from the scanner
| 
				 02 0E 02 00 00 08 45 4C 30 33 30 30 39 35 25 51 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00  | 
		
then we'll get the S/N (EL030095) of this device which is localed from 7th to 14th in the return message with HEX
- Example 2: activate/terminate scanning session for FM30
 
1) enter command trigger mode
send data to the scanner
| 
				 04 09 7E 00 08 01 00 00 D5 EF 41 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00  | 
		
acquire response from the scanner
| 
				 02 07 02 00 00 01 00 33 31 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00  | 
		
2) activate scanning session
send data to the scanner
| 
				 04 09 7E 00 08 01 00 02 01 02 DA 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00  | 
		
acquire response from the scanner
| 
				 02 07 02 00 00 01 00 33 31 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00  | 
		
3) terminate scanning session
send data to the scanner
| 
				 04 09 7E 00 08 01 00 02 02 32 B9 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00  | 
		
acquire response from the scanner
| 
				 02 07 02 00 00 01 00 33 31 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00  | 
		
- Example 3: activate/terminate scanning session for FM50
 
1) activate scanning session
| 
				 04 02 1B 31 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00  | 
		
2) terminate scanning session
| 
				 04 02 1B 30 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00  | 
		

												                    
															
								
						
					
						
					
						
					
					
					


										
										
										