When I use the IBM SurePos interface, how to config the beep parameter?

Firmware version required:

STORM-D.UQ101.CS.H03.2 and the later version

List

Command

Note

Format

30 01 10 f0 00 FreqLo FreqHi  DurationLo DurationHi  Volume 00

FreqLo FreqHi  refer to the below range list
DurationLo DurationHi   Duration75ms fixed value 4B 00
Volume 5,10,20 match to volume low middle high

 

30 01 10 f0 00 BC 02 4B 00 05 00

Frequency 700  Volume low

 

30 01 10 f0 00 BC 02 4B 00 0A 00

Frequency 700  Volume Middle

 

30 01 10 f0 00 BC 02 4B 00 14 00

Frequency 700  Volume High

 

30 01 10 f0 00 52 03 4B 00 05 00

Frequency 850 Volume low

 

30 01 10 f0 00 52 03 4B 00 0A 00

Frequency 850  Volume Middle

 

30 01 10 f0 00 52 03 4B 00 14 00

Frequency 850  Volume High

 

30 01 10 f0 00 84 03 4B 00 05 00

Frequency 900  Volume low

 

30 01 10 f0 00 84 03 4B 00 0A 00

Frequency 900  Volume Middle

 

30 01 10 f0 00 84 03 4B 00 14 00

Frequency 900  Volume High

 

30 01 10 f0 00 B6 03 4B 00 05 00

Frequency 950  Volume low

 

30 01 10 f0 00 B6 03 4B 00 0A 00

Frequency 950 Volume Middle

 

30 01 10 f0 00 B6 03 4B 00 14 00

Frequency 950  Volume High

 

30 01 10 f0 00 DC 05 4B 00 05 00

Frequency 1500  Volume low

 

30 01 10 f0 00 DC 05 4B 00 0A 00

Frequency 1500  Volume Middle

 

30 01 10 f0 00 DC 05 4B 00 14 00

Frequency 1500  Volume High

Frequency

hex config value in command FreqLo FreqHi

Note

700

BC 02

 

850

52 03

 

900

84 03

 

950

B6 03

 

1500

DC 05

 

Volume

hex config value in command

Note

5

05

low volume

10

0A

middle volume

20

14

high volume