LINKS
LINKS
HR1550 Output data Edit
작가: Ivan 시간: 27th Jul 2021
와 공유:


EAN128   Output Demand:08435420422477

 

Way1:

1、Scan the “enter setup”barcode

 

2、Scan the “Add Data Format”barcode

 

3、Scan the”Format_0”barcode

 

4、Scan the”6”barcode

 

 

5、Scan the “9” barcode for 3 times.

6. Scan the “0” barcode

7. Scan the “0” barcode

8.Scan the “3” barcode

9、Scan the “9” barcode for 4 times.

 

10、Scan the “F” barcode

11、Scan the “5”barcode

 

12、Scan the “0”barcode

 

 

 

 

13、Scan the “2”barcode


14Scan the “F” barcode

15、Scan the “2”barcode

 

16、Scan the “1” barcode

 

 

 

17、Scan the “4” barcode

 

18、Scan the “0” barcode

 

19、Scan the “0” barcode

 

20、Scan the “save” barcode

 

21、Scan the “Enable Data Formatter,Not Required,Keep Prefix/Suffix” barcode

 

 

 

 

Way two:

 send command to HR15 via serial com or USB CDC communication interface

Send: (069990039999F502F21400))));$$$$#99904504;%%%%

Response: S@@@@!99904504;^^^^

 